LEMON Manuals: Even more car manuals for everyone
Home >> Nissan-Datsun >> 2004 >> Sentra SE-R >> Repair and Diagnosis >> External Pages >> Different car >> Section 746 (Engine Cooling System) >> Cooling Fan >> Removal and Installation >> Installation

Removal and Installation: Installation

WARNING: This page is about a different car, the 2003 Infiniti M45. However, it is still accessible from the selected car via links, so may be relevant.

Install in the reverse order of removal referring the following.

Attaching the fluid pipe fixing clip: 

If the fluid pipe fixing clip has been removed from the installation holes, it must be replaced with a new clip.

Adding cooling fan fluid and bleeding air: 

The procedure below is for adding cooling fan fluid and bleeding air from the piping.

CAUTION:
  • Do not reuse the used fluid which was drained out.
  • Use genuine Nissan Power Steering Fluid or equivalent. Refer to "RECOMMENDED FLUIDS AND LUBRICANTS ".
NOTE: The total fluid volume is 777 ml (26. 3 US floz, 27. 4 Imp floz) (with the cold maximum on the level gauge when the engine is cold).
  1. Add fluid to the reservoir tank until the fluid reaches the upper limit of the "HOT" level on the level gauge. For the fluid level, refer to "INSPECTION AFTER INSTALLATION ".
  2. Start the engine.
  3. Run the engine at idle speed for a few minutes. Then check the fluid level. If the level has decreased, add fluid.
    CAUTION:
    • Be careful not to touch the fan while it is rotating.
    • Be sure to add fluid as necessary. If the fluid runs out in the reservoir tank, air will be taken in.
    NOTE:
    • With the engine operating, the reservoir tank cap can be removed to check the fluid level.
    • Immediately after starting, certain noise will come from the fluid pump. This is caused by air taken in to the piping and will gradually disappear.
  4. Continue with step  3 until the level of the fluid stops decreasing.
  5. Stop the engine and disconnect the harness connector for the cooling fan speed control solenoid valve.
    NOTE: When the solenoid valve harness is disconnected, the fan will operate at full speed.
  6. Start the engine. Repeat step  3 until the fluid level stops decreasing and air bubbles stop coming out.
  7. Stop the engine. Connect the harness connector for the cooling fan speed control solenoid valve.
    Fig 1: Identifying Fluid Reservoir Tank (Cooling Fan) And Harness Connector
    G02021125Courtesy of NISSAN MOTOR CO., U.S.A.