  1. CHECK A/C RELAY CONTROL CIRCUIT
    1. Turn power switch OFF.
    2. Remove A/C relay.
    3. Check the voltage between A/C relay harness connector terminals.
      VOLTAGE REFERENCE CHART

      A/C relay Voltage
      Connector + -
      Terminal
      E52 1 2 0 V
    4. Turn power switch ON.
    5. Check the voltage between A/C relay harness connector terminals.
    VOLTAGE REFERENCE CHART

    A/C relay Voltage
    Connector + -
    Terminal
    E52 1 2 12V battery voltage

    Is the inspection result normal? 

    YES: Go to  8.

    NO: Go to 2.

  2. CHECK SSOFF RELAY POWER SUPPLY-I

    Check the voltage between A/C relay harness connector and ground.

    VOLTAGE REFERENCE CHART

    + - Voltage
    A/C relay
    Connector Terminal
    E52 1 Ground 12V battery voltage

    Is the inspection result normal? 

    YES: Go to  5.

    NO: Go to 3.

  3. CHECK SSOFF RELAY POWER SUPPLY-II

    Check the voltage between IPDM E/R harness connector and ground.

    VOLTAGE REFERENCE CHART

    + - Voltage
    IPDM E/R
    Connector Terminal
    E14 36 Ground 12V battery voltage

    Is the inspection result normal? 

    YES: Go to 4.

    NO: Check SSOFF relay routing circuit. Refer to "DIAGNOSIS PROCEDURE ".

  4. CHECK A/C RELAY POWER SUPPLY CIRCUIT
    1. Turn power switch OFF.
    2. Disconnect IPDM E/R harness connector.
    3. Check the continuity between A/C relay harness connector and IPDM E/R harness connector.
    CONTINUITY REFERENCE CHART

    + - Continuity
    A/C relay IPDM E/R
    Connector Terminal Connector Terminal
    E52 1 E14 36 Existed

    Is the inspection result normal? 

    YES: Check intermittent incident. Refer to "INTERMITTENT INCIDENT ".

    NO: Repair or replace error-detected parts.

  5. CHECK A/C RELAY CONTROL SIGNAL CIRCUIT
    1. Turn power switch OFF.
    2. Disconnect VCM harness connector.
    3. Check the continuity between A/C relay harness connector and VCM harness connector.
      CONTINUITY REFERENCE CHART

      + - Continuity
      A/C relay VCM
      Connector Terminal Connector Terminal
      E52 2 E61 5 Existed
    4. Also check harness for short to ground and short to power.

    Is the inspection result normal? 

    YES: Go to 6.

    NO: Repair or replace error-detected parts.

  6. CHECK VCM GROUND CIRCUIT

    Check the continuity between VCM harness connector and ground.

    CONTINUITY REFERENCE CHART

    + - Continuity
    IPDM E/R
    Connector Terminal
    E61 4 Ground Existed
    8
    E63 111
    112

    Is the inspection result normal? 

    YES: Go to 7.

    NO: Repair or replace error-detected parts.

  7. CHECK INTERMITTENT INCIDENT

    Check intermittent incident. Refer to "INTERMITTENT INCIDENT ".

    Is the inspection result normal? 

    YES: Replace VCM. Refer to "REMOVAL AND INSTALLATION ".

    NO: Repair or replace error-detected parts.

  8. CHECK BATTERY POWER SUPPLY
    1. Turn power switch OFF.
    2. Check the voltage between A/C relay harness connector and ground.
    VOLTAGE REFERENCE CHART

    + - Voltage
    A/C relay
    Connector Terminal
    E52 3 Ground 12V battery voltage
    6

    Is the inspection result normal? 

    YES: Go to  11.

    NO: Go to 9.

  9. CHECK FUSE
    1. Turn power switch OFF.
    2. Pull out #32 fuse.
    3. Check that the fuse is not fusing.

    Is the inspection result normal? 

    YES: Go to 10.

    NO: Replace the fuse after repairing the applicable circuit.

  10. CHECK BATTERY POWER SUPPLY CIRCUIT

    Check the continuity between A/C relay harness connector and fuse harness connector.

    CONTINUITY REFERENCE CHART

    + - Continuity
    A/C relay
    Connector Terminal
    E52 3 #32 fuse terminal Existed
    6

    Is the inspection result normal? 

    YES: Check intermittent incident. Refer to "INTERMITTENT INCIDENT ".

    NO: Repair or replace error-detected parts.

  11. CHECK A/C RELAY

    Refer to "COMPONENT INSPECTION (A/C RELAY) ".

    Is the inspection result normal? 

    YES: INSPECTION END

    NO: Replace A/C relay.