Diagnosis Procedure
- CHECK A/C RELAY CONTROL CIRCUIT
- Turn power switch OFF.
- Remove A/C relay.
- Check the voltage between A/C relay harness connector terminals.VOLTAGE REFERENCE CHART
A/C relay Voltage Connector + - Terminal E52 1 2 0 V - Turn power switch ON.
- Check the voltage between A/C relay harness connector terminals.
VOLTAGE REFERENCE CHARTA/C relay Voltage Connector + - Terminal E52 1 2 12V battery voltage Is the inspection result normal?
YES: Go to 8.
NO: Go to 2.
- CHECK SSOFF RELAY POWER SUPPLY-I
Check the voltage between A/C relay harness connector and ground.
VOLTAGE REFERENCE CHART+ - Voltage A/C relay Connector Terminal E52 1 Ground 12V battery voltage Is the inspection result normal?
YES: Go to 5.
NO: Go to 3.
- CHECK SSOFF RELAY POWER SUPPLY-II
Check the voltage between IPDM E/R harness connector and ground.
VOLTAGE REFERENCE CHART+ - Voltage IPDM E/R Connector Terminal E14 36 Ground 12V battery voltage Is the inspection result normal?
YES: Go to 4.
NO: Check SSOFF relay routing circuit. Refer to "DIAGNOSIS PROCEDURE ".
- CHECK A/C RELAY POWER SUPPLY CIRCUIT
- Turn power switch OFF.
- Disconnect IPDM E/R harness connector.
- Check the continuity between A/C relay harness connector and IPDM E/R harness connector.
CONTINUITY REFERENCE CHART+ - Continuity A/C relay IPDM E/R Connector Terminal Connector Terminal E52 1 E14 36 Existed Is the inspection result normal?
YES: Check intermittent incident. Refer to "INTERMITTENT INCIDENT ".
NO: Repair or replace error-detected parts.
- CHECK A/C RELAY CONTROL SIGNAL CIRCUIT
- Turn power switch OFF.
- Disconnect VCM harness connector.
- Check the continuity between A/C relay harness connector and VCM harness connector.CONTINUITY REFERENCE CHART
+ - Continuity A/C relay VCM Connector Terminal Connector Terminal E52 2 E61 5 Existed - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES: Go to 6.
NO: Repair or replace error-detected parts.
- CHECK VCM GROUND CIRCUIT
Check the continuity between VCM harness connector and ground.
CONTINUITY REFERENCE CHART+ - Continuity IPDM E/R Connector Terminal E61 4 Ground Existed 8 E63 111 112 Is the inspection result normal?
YES: Go to 7.
NO: Repair or replace error-detected parts.
- CHECK INTERMITTENT INCIDENT
Check intermittent incident. Refer to "INTERMITTENT INCIDENT ".
Is the inspection result normal?
YES: Replace VCM. Refer to "REMOVAL AND INSTALLATION ".
NO: Repair or replace error-detected parts.
- CHECK BATTERY POWER SUPPLY
- Turn power switch OFF.
- Check the voltage between A/C relay harness connector and ground.
VOLTAGE REFERENCE CHART+ - Voltage A/C relay Connector Terminal E52 3 Ground 12V battery voltage 6 Is the inspection result normal?
YES: Go to 11.
NO: Go to 9.
- CHECK FUSE
- Turn power switch OFF.
- Pull out #32 fuse.
- Check that the fuse is not fusing.
Is the inspection result normal?
YES: Go to 10.
NO: Replace the fuse after repairing the applicable circuit.
- CHECK BATTERY POWER SUPPLY CIRCUIT
Check the continuity between A/C relay harness connector and fuse harness connector.
CONTINUITY REFERENCE CHART+ - Continuity A/C relay Connector Terminal E52 3 #32 fuse terminal Existed 6 Is the inspection result normal?
YES: Check intermittent incident. Refer to "INTERMITTENT INCIDENT ".
NO: Repair or replace error-detected parts.
- CHECK A/C RELAY
Refer to "COMPONENT INSPECTION (A/C RELAY) ".
Is the inspection result normal?
YES: INSPECTION END
NO: Replace A/C relay.