Diagnosis Procedure
- CHECK FUSE
- Turn power switch OFF.
- Pull out #43 fuse.
- Check that the fuse is not fusing.
Is the inspection result normal?
YES: Go to 2.
NO: Replace the fuse after repairing the applicable circuit.
- CHECK BATTERY POWER SUPPLY-I
- Insert the fuse.
- Check the voltage between IPDM E/R harness connector and ground.
VOLTAGE REFERENCE CHART+ - Voltage IPDM E/R Connector Terminal E14 41 Ground Battery voltage Is the inspection result normal?
YES: Go to 6.
NO: Go to 3.
- CHECK BATTERY POWER SUPPLY-II
Check the voltage between IPDM E/R harness connector and ground.
VOLTAGE REFERENCE CHART+ - Voltage IPDM E/R Connector Terminal E9 2 Ground Battery voltage Is the inspection result normal?
YES: Go to 5.
NO: Go to 4.
- CHECK FUSIBLE LINK
- Remove #D fusible link.
- Check that the fusible link is not fusing.
Is the inspection result normal?
YES: Check power supply circuit for battery power supply.
NO: Replace the fusible link after repairing the applicable circuit.
- CHECK SSOFF RELAY CONTROL CIRCUIT FOR SHORT TO GROUND
- Turn power switch OFF.
- Disconnect VCM harness connector.
- Check harness for short to ground between IPDM E/R harness connector and VCM harness connector.
CONTINUITY REFERENCE CHART+ - Continuity IPDM E/R VCM Connector Terminal Connector Terminal E14 41 E61 7 Existed Is the inspection result normal?
YES: Replace IPDM E/R. Refer to "REMOVAL AND INSTALLATION ".
NO: Repair or replace error-detected parts.
- CHECK SSOFF RELAY CONTROL SIGNAL
- Turn power switch ON.
- Check the voltage between IPDM E/R harness connector and ground.
VOLTAGE REFERENCE CHART+ - Voltage (Approx.) IPDM E/R Connector Terminal E14 41 Ground 0 V Is the inspection result normal?
YES: Go to 10.
NO: Go to 7.
- CHECK SS OFF RELAY CONTROL SIGNAL CIRCUIT
- Turn power switch OFF.
- Disconnect VCM harness connector.
- Check the continuity between IPDM E/R harness connector and VCM harness connector.CONTINUITY REFERENCE CHART
+ - Continuity IPDM E/R VCM Connector Terminal Connector Terminal E14 41 E61 7 Existed - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES: Go to 8.
NO: Repair or replace error-detected parts.
- CHECK VCM GROUND CIRCUIT
Check the continuity between VCM harness connector and ground.
CONTINUITY REFERENCE CHART+ - Continuity IPDM E/R Connector Terminal E61 4 Ground Existed 8 E63 111 112 Is the inspection result normal?
YES: Go to 9.
NO: Repair or replace error-detected parts.
- CHECK INTERMITTENT INCIDENT
Check intermittent incident. Refer to "INTERMITTENT INCIDENT ".
Is the inspection result normal?
YES: Replace VCM. Refer to "REMOVAL AND INSTALLATION ".
NO: Repair or replace error-detected parts.
- CHECK SSOFF RELAY OUTPUT VOLTAGE
Check the voltage between IPDM E/R harness connector and ground.
VOLTAGE REFERENCE CHART+ - Voltage IPDM E/R Connector Terminal E14 36 Ground 12V battery voltage Is the inspection result normal?
YES: INSPECTION END
NO: Replace IPDM E/R. Refer to "REMOVAL AND INSTALLATION ".