False Alarm
- Using hand-held transmitter, deactivate alarm. Turn ignition off. Remove alarm control module. See Figure
. Disconnect all alarm loops (door, trunk, hood, etc.) except ignition. Disconnect following wiring from relay center and insulate with tape or insulators:
- Door contacts (Yellow/White wire at terminal "T").
- Hood alarm loop (Yellow/Black wire at terminal FH).
- Trunk alarm loop (Blue/Brown wire at terminal RH).
- Disconnect sensor 4-pin connector (Guard Alarm I and II). Turn ignition off. Reinstall alarm control module. Close all doors, hood, and trunk lid. Activate alarm. If alarm continues, check false alarm at ignition voltage supply circuit.