Inspection Procedure
WARNING: This page is about a different car, the 2006 Toyota Sienna. However, it is still accessible from the selected car via links, so may be relevant.
- PERFORM ACTIVE TEST BY INTELLIGENT TESTER
- Connect the intelligent tester to DLC3.
- Turn the ignition switch ON and push the intelligent tester main switch ON.
- Select the item below in the ACTIVE TEST and then check that the relay operates.
BODY NO. 1:
BODY NO. 1Item Test Details Diagnostic Note DRL RELAY (Test Details)
Turn daytime running light relay ON / OFF (Vehicle Condition)
Ignition SW is ON, engine is stopped and light control SW is in OFF position.-
OK: PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE
NG: GO TO NEXT STEP
- INSPECT DRL NO. 2 RELAY
- Inspect DRL No. 2 Relay continuity.
Resistance
DRL NO. 2 RELAYTester Connection Condition Specified Condition 3 - 5 Always 10 kΩ or higher 3 - 5 Apply B+ between the terminal 1 and 2 Below 1 Ω
NG: REPLACE DRL NO. 2 RELAY
OK: GO TO NEXT STEP
- Inspect DRL No. 2 Relay continuity.
- CHECK HARNESS AND CONNECTOR (POWER SOURCE)
- Disconnect the connector from the instrument panel junction block assembly.
- Measure the voltage according to the value(s) in the table below.
Voltage
POWER SOURCETester Connection Condition Specified Condition 1C-23 - Body ground Always 10 to 14 V
NG: REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: GO TO NEXT STEP
- INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY
- Reconnect the connector to the instrument panel junction block assembly.
- Measure the voltage according to the value(s) in INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY
.
Voltage
INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLYTester Connection Condition Specified Condition 1C-23 - Body ground Ignition switch: OFF 10 to 14 V 1C-23 - Body ground Ignition switch: ON Below 1 V
NG: REPLACE INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY
OK: GO TO NEXT STEP
- INSPECT RELAY (DRL NO. 3, DRL NO. 4)
- Inspect DRL NO. 4 Relay continuity.
Resistance
DRL NO. 4 RELAYTester Connection Condition Specified Condition 3 - 5 Always 10 kΩ or higher 3 - 5 Apply B+ between the terminal 1 and 2 Below 1 Ω - Inspect DRL NO. 3 Relay continuity.
Resistance
DRL NO. 3 RELAYTester Connection Condition Specified Condition 3 - 4 Always Below 1 Ω 3 - 4 Apply B+ between the terminal 1 and 2 10 kΩ or higher 3 - 5 Always 10 kΩ or higher 3 - 5 Apply B+ between the terminal 1 and 2 Below 1 Ω
NG: REPLACE RELAY
OK: GO TO NEXT STEP
- Inspect DRL NO. 4 Relay continuity.
- INSPECT DAYTIME RESISTER
- Measure the resistance according to the value(s) in DAYTIME RESISTER
.
Resistance
DAYTIME RESISTERTester Connection Condition Specified Condition 1 - 2 Always 0.94 to 1.04 Ω
NG: REPLACE DAYTIME RESISTER
OK: REPAIR OR REPLACE HARNESS OR CONNECTOR
- Measure the resistance according to the value(s) in DAYTIME RESISTER
.