1GR-FE 4.0L

TID $07 A/F SENSOR HEATER

TLT CID Unit Conversion Description of Test Data Description of Test Limit
1 $01 Multiply by 0.00017
(A)
Maximum heater current
(Bank 1)
Malfunction criteria for A/F sensor heater
1 $10 Multiply by 0.00017
(A)
Maximum heater current
(Bank 2)
Malfunction criteria for A/F sensor heater
TID $04 HO2S HEATER

TLT CID Unit Conversion Description of Test Data Description of Test Limit
1 $02 Multiply by 0.000076
(A)
Maximum HO2S heater current
(Bank 1 Sensor 2)
Malfunction threshold for HO2S heater
1 $20 Multiply by 0.000076
(A)
Maximum HO2S heater current
(Bank 2 Sensor 2)
Malfunction threshold for HO2S heater
TID $08 THERMOSTAT

TLT CID Unit Conversion Description of Test Data Description of Test Limit
1 $01 Multiply by 0.625 and subtract 40 (°C) ECT sensor output when estimated ECT has reached to malfunction criterion Malfunction criteria for thermostat
O2S TEST RESULT

Test ID Test Item Description Unit Conversion Unit Standard Value
$07 Output Voltage Minimum rear HO2 sensor output voltage Multiply by 0.005 V Less than TEST LIMIT
$08 Output Voltage Maximum rear HO2 sensor output voltage Multiply by 0.005 V More than TEST LIMIT
$91 OSC Maximum OSC in catalytic converter Multiply by 0.0156 g Less than TEST LIMIT
TID $01 CATALYST (ACTIVE A/F CONTROL METHOD)

TLT CID Unit Conversion Description of Test Data Description of Test Limit
1 $01 Multiply by 0.0078 (no dimension) Oxygen storage capacity (bank 1): Calculated by HO2S 2 output Malfunction criteria for catalyst deterioration
1 $02 Multiply by 0.0078 (no dimension) Oxygen storage capacity (bank 2): Calculated by HO2S 2 output Malfunction criteria for catalyst deterioration
TID $06: A/F SENSOR (ACTIVE A/F CONTROL METHOD)

TLT CID Unit Conversion Description of Test Data Description of Test Limit
1 $01 Multiply by 0.0003 (V) Cumulative A/F sensor locus length (Bank 1) Lower malfunction criterion for A/F sensor
0 $01 Multiply by 0.0003 (V) Cumulative A/F sensor locus length (Bank 1) Upper malfunction criterion for A/F sensor
1 $11 Multiply by 0.0003 (V) Cumulative A/F sensor locus length (Bank 2) Lower malfunction criterion for A/F sensor
0 $11 Multiply by 0.0003 (V) Cumulative A/F sensor locus length (Bank 2) Upper malfunction criterion for A/F sensor
1 $02 Multiply by 0.000039 (A) A/F sensor current (Bank 1) Lower malfunction criterion for A/F sensor
0 $02 Multiply by 0.000039 (A) A/F sensor current (Bank 1) Upper malfunction criterion for A/F sensor
1 $12 Multiply by 0.000039 (A) A/F sensor current (Bank 2) Lower malfunction criterion for A/F sensor
0 $12 Multiply by 0.000039 (A) A/F sensor current (Bank 2) Upper malfunction criterion for A/F sensor
EVAP-KEY-OFF MONITOR

MID TID Scaling Description of Test Value Minimum Test Limit Maximum Test Limit
$3D $C9 Multiply by 0.01 (KPa) Test value for small leak (P0456): Refer to pressure D(1). Minimum test limit for small leak Maximum test limit for small leak
$3D $CA Multiply by 0.01 (kPa) Test value for gross leak (P0455): Refer to pressure E(1). Minimum test limit for gross leak Maximum test limit for gross leak
$3D $CB Multiply by 0.01 (kPa) Test value for vacuum pump stuck OFF (P2401): Refer to pressure A(1). Minimum test limit for vacuum pump stuck OFF Maximum test limit for vacuum pump stuck OFF
$3D $CD Multiply by 0.01 (kPa) Test value for vacuum pump stuck ON (P2402): Refer to pressure A(1). Minimum test limit for vacuum pump stuck ON Maximum test limit for vacuum pump stuck ON
$3D $CE Multiply by 0.01 (kPa) Test value for vent valve stuck OFF (vent) (P2420): Refer to pressure C(1). Minimum test limit for vent valve stuck ON Maximum test limit for vent valve stuck ON
$3D $CF Multiply by 0.01 (kPa) Test value for vent valve stuck ON (closed) (P2419): Refer to pressure A(1). Minimum test limit for vent valve stuck OFF Maximum test limit for vent valve stuck OFF
$3D $D0 Multiply by 0.01 (kPa) Test value for 0.02 inch orifice low flow (P043E): Refer to pressure B(1). Minimum test limit for 0.02 inch orifice low flow Maximum test limit for 0.02 inch orifice low flow
$3D $D1 Multiply by 0.01 (kPa) Test value for 0.02 inch orifice high flow (P043F): Refer to pressure A(1). Minimum test limit for 0.02 inch orifice high flow Maximum test limit for 0.02 inch orifice high flow
$3D $D4 Multiply by 0.01 (kPa) Test value for purge VSV stuck close (P0441); Refer to pressure F(1). Minimum test limit for purge VSV stuck close Maximum test limit for purge VSV stuck close
$3D $D5 Multiply by 0.01 (kPa) Test value for purge VSV stuck open (P0441): Refer to pressure E(1). Minimum test limit for purge VSV stuck open Maximum test limit for purge VSV stuck open
$3D $D7 Multiply by 0.01 (kPa) Test value for purge flow (P0441): Refer to pressure G(1). Minimum test limit for purge flow Maximum test limit for purge flow
(1) Pressure A to G are indicated as shown in the diagram below.
Fig 1: Key-Off Monitor And Purge Flow Monitor - Description Diagram
G02648135Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002