1GR-FE 4.0L
TID $07 A/F SENSOR HEATER
| TLT | CID | Unit Conversion | Description of Test Data | Description of Test Limit |
|---|---|---|---|---|
| 1 | $01 | Multiply by 0.00017 (A) |
Maximum heater current (Bank 1) |
Malfunction criteria for A/F sensor heater |
| 1 | $10 | Multiply by 0.00017 (A) |
Maximum heater current (Bank 2) |
Malfunction criteria for A/F sensor heater |
TID $04 HO2S HEATER
| TLT | CID | Unit Conversion | Description of Test Data | Description of Test Limit |
|---|---|---|---|---|
| 1 | $02 | Multiply by 0.000076 (A) |
Maximum HO2S heater current (Bank 1 Sensor 2) |
Malfunction threshold for HO2S heater |
| 1 | $20 | Multiply by 0.000076 (A) |
Maximum HO2S heater current (Bank 2 Sensor 2) |
Malfunction threshold for HO2S heater |
TID $08 THERMOSTAT
| TLT | CID | Unit Conversion | Description of Test Data | Description of Test Limit |
|---|---|---|---|---|
| 1 | $01 | Multiply by 0.625 and subtract 40 (°C) | ECT sensor output when estimated ECT has reached to malfunction criterion | Malfunction criteria for thermostat |
O2S TEST RESULT
| Test ID | Test Item | Description | Unit Conversion | Unit | Standard Value |
|---|---|---|---|---|---|
| $07 | Output Voltage | Minimum rear HO2 sensor output voltage | Multiply by 0.005 | V | Less than TEST LIMIT |
| $08 | Output Voltage | Maximum rear HO2 sensor output voltage | Multiply by 0.005 | V | More than TEST LIMIT |
| $91 | OSC | Maximum OSC in catalytic converter | Multiply by 0.0156 | g | Less than TEST LIMIT |
TID $01 CATALYST (ACTIVE A/F CONTROL METHOD)
| TLT | CID | Unit Conversion | Description of Test Data | Description of Test Limit |
|---|---|---|---|---|
| 1 | $01 | Multiply by 0.0078 (no dimension) | Oxygen storage capacity (bank 1): Calculated by HO2S 2 output | Malfunction criteria for catalyst deterioration |
| 1 | $02 | Multiply by 0.0078 (no dimension) | Oxygen storage capacity (bank 2): Calculated by HO2S 2 output | Malfunction criteria for catalyst deterioration |
TID $06: A/F SENSOR (ACTIVE A/F CONTROL METHOD)
| TLT | CID | Unit Conversion | Description of Test Data | Description of Test Limit |
|---|---|---|---|---|
| 1 | $01 | Multiply by 0.0003 (V) | Cumulative A/F sensor locus length (Bank 1) | Lower malfunction criterion for A/F sensor |
| 0 | $01 | Multiply by 0.0003 (V) | Cumulative A/F sensor locus length (Bank 1) | Upper malfunction criterion for A/F sensor |
| 1 | $11 | Multiply by 0.0003 (V) | Cumulative A/F sensor locus length (Bank 2) | Lower malfunction criterion for A/F sensor |
| 0 | $11 | Multiply by 0.0003 (V) | Cumulative A/F sensor locus length (Bank 2) | Upper malfunction criterion for A/F sensor |
| 1 | $02 | Multiply by 0.000039 (A) | A/F sensor current (Bank 1) | Lower malfunction criterion for A/F sensor |
| 0 | $02 | Multiply by 0.000039 (A) | A/F sensor current (Bank 1) | Upper malfunction criterion for A/F sensor |
| 1 | $12 | Multiply by 0.000039 (A) | A/F sensor current (Bank 2) | Lower malfunction criterion for A/F sensor |
| 0 | $12 | Multiply by 0.000039 (A) | A/F sensor current (Bank 2) | Upper malfunction criterion for A/F sensor |
EVAP-KEY-OFF MONITOR
| MID | TID | Scaling | Description of Test Value | Minimum Test Limit | Maximum Test Limit | ||
|---|---|---|---|---|---|---|---|
| $3D | $C9 | Multiply by 0.01 (KPa) | Test value for small leak (P0456): Refer to pressure D(1). | Minimum test limit for small leak | Maximum test limit for small leak | ||
| $3D | $CA | Multiply by 0.01 (kPa) | Test value for gross leak (P0455): Refer to pressure E(1). | Minimum test limit for gross leak | Maximum test limit for gross leak | ||
| $3D | $CB | Multiply by 0.01 (kPa) | Test value for vacuum pump stuck OFF (P2401): Refer to pressure A(1). | Minimum test limit for vacuum pump stuck OFF | Maximum test limit for vacuum pump stuck OFF | ||
| $3D | $CD | Multiply by 0.01 (kPa) | Test value for vacuum pump stuck ON (P2402): Refer to pressure A(1). | Minimum test limit for vacuum pump stuck ON | Maximum test limit for vacuum pump stuck ON | ||
| $3D | $CE | Multiply by 0.01 (kPa) | Test value for vent valve stuck OFF (vent) (P2420): Refer to pressure C(1). | Minimum test limit for vent valve stuck ON | Maximum test limit for vent valve stuck ON | ||
| $3D | $CF | Multiply by 0.01 (kPa) | Test value for vent valve stuck ON (closed) (P2419): Refer to pressure A(1). | Minimum test limit for vent valve stuck OFF | Maximum test limit for vent valve stuck OFF | ||
| $3D | $D0 | Multiply by 0.01 (kPa) | Test value for 0.02 inch orifice low flow (P043E): Refer to pressure B(1). | Minimum test limit for 0.02 inch orifice low flow | Maximum test limit for 0.02 inch orifice low flow | ||
| $3D | $D1 | Multiply by 0.01 (kPa) | Test value for 0.02 inch orifice high flow (P043F): Refer to pressure A(1). | Minimum test limit for 0.02 inch orifice high flow | Maximum test limit for 0.02 inch orifice high flow | ||
| $3D | $D4 | Multiply by 0.01 (kPa) | Test value for purge VSV stuck close (P0441); Refer to pressure F(1). | Minimum test limit for purge VSV stuck close | Maximum test limit for purge VSV stuck close | ||
| $3D | $D5 | Multiply by 0.01 (kPa) | Test value for purge VSV stuck open (P0441): Refer to pressure E(1). | Minimum test limit for purge VSV stuck open | Maximum test limit for purge VSV stuck open | ||
| $3D | $D7 | Multiply by 0.01 (kPa) | Test value for purge flow (P0441): Refer to pressure G(1). | Minimum test limit for purge flow | Maximum test limit for purge flow | ||
|
|||||||