2ZZ-GE 1.8L
TID $04: HO2S HEATER
| TLT | CID | Unit Conversion | Description of Test Data | Description of Test Limit |
|---|---|---|---|---|
| 1 | $01 | Multiplied by 0.000076 (A) | Maximum HO2S heater current (Bank 1 Sensor 1) | Malfunction threshold for HO2S heater |
| 1 | $02 | Multiplied by 0.000076 (A) | Maximum HO2S heater current (Bank 1 Sensor 2) | Malfunction threshold for HO2S heater |
TID $08: THERMOSTAT
| TLT | CID | Unit Conversion | Description of Test Data | Description of Test Limit |
|---|---|---|---|---|
| 1 | $01 | Multiply by 0.625 and subtract 40 (°C) | ECT sensor output when estimated ECT has reached to malfunction criterion | Malfunction criteria for thermostat |
FRONT HO2S VOLTAGE MONITOR
| TEST ID | Description of TEST DATA | Conversion Factor | Unit |
|---|---|---|---|
| $07 | Minimum front HO2S voltage | Multiplied by 0.005 | V |
| $08 | Maximum front HO2S voltage | Multiplied by 0.005 | V |
FRONT HO2S FREQUENCY MONITOR (CRUISE)
| TEST ID | Description of TEST DATA | Conversion Factor | Unit |
|---|---|---|---|
| $90 | Remained value of that average of switching frequency is subtracted from average of switching frequency threshold | Multiply by 0.04096 plus 5.2 | sec. |
REAR HO2S VOLTAGE MONITOR
| TEST ID | Description of TEST DATA | Conversion Factor | Unit |
|---|---|---|---|
| $07 Minimum rear | HO2S voltage | Multiplied by 0.005 | V |
| $08 Maximum rear | HO2S voltage | Multiplied by 0.005 | V |
O2S TEST RESULT
| TEST ID | Description of TEST DATA | Conversion Factor | Unit |
|---|---|---|---|
| $31 | Time to change from Lean (<0.4V) to Rich (0.5V) | Multiplied by 0.04 | sec. |
| $32 | Time to change from Rich (0.5 V) to Lean (<0.4 V) | Multiplied by 0.04 | sec. |
REAR HO2S SLOW RESPONSE MONITOR
| TEST ID | Description of TEST DATA | Conversion Factor | Unit |
|---|---|---|---|
| $37 | Time until rear HO2S voltage drops to 0.2 V after fuel-cut starting | Multiplied by 0.04 | sec. |
REAR HO2S ELEMENT MONITOR
| TEST ID | Description of TEST DATA | Conversion Factor | Unit |
|---|---|---|---|
| $81 | Percentage of monitoring time when the HO2S voltage is less than 0.05 V | Multiplied by 0.3906 | % |
| $84 | Percentage of monitoring time when the HO2S voltage is more than 0.7 V | Multiplied by 0.3906 | % |
| $85 | Time when the HO2S voltage is 0.45 V or more | Multiplied by 0.2621 | sec. |
| $87 | Percentage of monitoring time when the HO2S voltage is 0.45 V or more | Multiplied by 0.3906 | % |
TID $01: CATALYST - SENSOR 1 HO2S, SENSOR 2 HO2S
| TLT | CID | Unit Conversion | Description of Test Data | Description of Test Limit |
|---|---|---|---|---|
| 0 | $01 | Multiplied by 0.0078 (no dimension) | Catalyst deterioration level (bank 1): Determined by waveforms of HO2S 1 and 2 | Malfunction criteria for catalyst deterioration |
TID $02: EVAP SYSTEM - VACUUM MONITOR
| TLT | CID | Unit Conversion | Description of Test Data | Description of Test Limit |
|---|---|---|---|---|
| 1 | $01 | Multiplied by 0.0916 (mmHg) | Test value of EVAP VSV: Determined by fuel tank pressure change during vacuum introduction | Malfunction criteria for EVAP VSV |
| 1 | $02 | Multiplied by 0.0458 subtract 2.93 (mmHg) | Test value of canister closed valve (CCV) and bypass VSV: Determined by fuel tank pressure change at switching over CCV and bypass VSV | Malfunction criteria for CCV and bypass VSV |
| 0 | $03 | Multiplied by 0.0458 (mmHg) | Test value of 0.04 inch leak: Determined by fuel tank pressure change | Malfunction criteria for 0.04 inch leak |
| 0 | $04 | Multiplied by 0.0458 (mmHg) | Test value of 0.02 inch leak: Determined by fuel tank pressure change | Malfunction criteria for 0.02 inch leak |
TID OA: SECONDARY AIR INJECTION
| TLT | CID | Unit Conversion | Description of Test Data | Description of Test Limit |
|---|---|---|---|---|
| 0 | $01 | Multiplied by 65.536 (no dimension) | Test value of AIR system malfunction | Malfunction criteria for AIR system malfunction |
| 1 | $02 | Multiplied by 8.192 (no dimension) | Test value of AIR control valve stuck open | Malfunction criteria for AIR control valve stuck open |
| 1 | $03 | Multiplied by 8.192 (no dimension) | Test value of AIR pump stuck ON | Malfunction criteria for AIR pump stuck ON |