1ZZ-FE 1.8L
TID $04: HO2S HEATER
| TLT | CID | Unit Conversion | Description of Test Data | Description of Test Limit |
|---|---|---|---|---|
| 1 | $01 | Multiply by 0.000076 (A) | Maximum HO2S heater current (Bank 1 Sensor 1) | Malfunction threshold for HO2S heater |
| 1 | $02 | Multiply by 0.000076 (A) | Maximum HO2S heater current (Bank 1 Sensor 2) | Malfunction threshold for HO2S heater |
TID $08: THERMOSTAT
| TLT | CID | Unit Conversion | Description of Test Data | Description of Test Limit |
|---|---|---|---|---|
| 1 | $01 | Multiply by 0.625 and subtract 40 (°C) | ECT sensor output when estimated ECT has reached to malfunction criterion | Malfunction criteria for thermostat |
FRONT HO2S VOLTAGE MONITOR
| TEST ID | Description of TEST DATA | Conversion Factor | Unit | Standard Value of TEST LIMIT |
|---|---|---|---|---|
| $07 | Minimum front HO2S voltage | N/A | V | Between 0 and 0.4 V |
| $08 | Maximum front HO2S voltage | N/A | V | Between 0.55 and 1.275 V |
REAR HO2S VOLTAGE MONITOR
| TEST ID | Description of TEST DATA | Conversion Factor | Unit |
|---|---|---|---|
| $07 | Minimum rear HO2S voltage | N/A | V |
| $08 | Maximum rear HO2S voltage | N/A | V |
REAR HO2S SLOW RESPONSE MONITOR
| TEST ID | Description of TEST DATA | Conversion Factor | Unit |
|---|---|---|---|
| $37 | Until rear HO2S voltage drops to 0.2 V after fuel-cut starting | N/A | sec. |
REAR HO2S ELEMENT MONITOR
| TEST ID | Description of TEST DATA | Conversion Factor | Unit |
|---|---|---|---|
| $81 | Percentage of monitoring time when the HO2S voltage is less than 0.05 V | Multiplied by 0.3906 | % |
| $84 | Percentage of monitoring time when the HO2S voltage is more than 0.7 V | Multiplied by 0.3906 | % |
| $85 | Time when the HO2S voltage is 0.45 V or more | Multiplied by 0.2621 | sec. |
| $87 | Percentage of monitoring time when the HO2S voltage is more than 0.45 V | Multiplied by 0.3906 | % |
TID $01: CATALYST - SENSOR 1 HO2S, SENSOR 2 HO2S
| TLT | CID | Unit Conversion | Description of Test Data | Description of Test Limit |
|---|---|---|---|---|
| 0 | $01 | Multiplied by 0.0078 (no dimension) | Catalyst deterioration level (bank 1): Determined by waveforms of HO2S 1 and 2 | Malfunction criteria for catalyst deterioration |