LEMON Manuals: Even more car manuals for everyone
Home >> Toyota >> 2005 >> Matrix Base, FWD, Standard >> Repair and Diagnosis >> Engine Performance >> Mode 6 - 2005 TOYOTA >> CELICA >> 1ZZ-FE 1.8L

1ZZ-FE 1.8L

TID $04: HO2S HEATER

TLT CID Unit Conversion Description of Test Data Description of Test Limit
1 $01 Multiply by 0.000076 (A) Maximum HO2S heater current (Bank 1 Sensor 1) Malfunction threshold for HO2S heater
1 $02 Multiply by 0.000076 (A) Maximum HO2S heater current (Bank 1 Sensor 2) Malfunction threshold for HO2S heater
TID $08: THERMOSTAT

TLT CID Unit Conversion Description of Test Data Description of Test Limit
1 $01 Multiply by 0.625 and subtract 40 (°C) ECT sensor output when estimated ECT has reached to malfunction criterion Malfunction criteria for thermostat
FRONT HO2S VOLTAGE MONITOR

TEST ID Description of TEST DATA Conversion Factor Unit Standard Value of TEST LIMIT
$07 Minimum front HO2S voltage N/A V Between 0 and 0.4 V
$08 Maximum front HO2S voltage N/A V Between 0.55 and 1.275 V
REAR HO2S VOLTAGE MONITOR

TEST ID Description of TEST DATA Conversion Factor Unit
$07 Minimum rear HO2S voltage N/A V
$08 Maximum rear HO2S voltage N/A V
REAR HO2S SLOW RESPONSE MONITOR

TEST ID Description of TEST DATA Conversion Factor Unit
$37 Until rear HO2S voltage drops to 0.2 V after fuel-cut starting N/A sec.
REAR HO2S ELEMENT MONITOR

TEST ID Description of TEST DATA Conversion Factor Unit
$81 Percentage of monitoring time when the HO2S voltage is less than 0.05 V Multiplied by 0.3906 %
$84 Percentage of monitoring time when the HO2S voltage is more than 0.7 V Multiplied by 0.3906 %
$85 Time when the HO2S voltage is 0.45 V or more Multiplied by 0.2621 sec.
$87 Percentage of monitoring time when the HO2S voltage is more than 0.45 V Multiplied by 0.3906 %
TID $01: CATALYST - SENSOR 1 HO2S, SENSOR 2 HO2S

TLT CID Unit Conversion Description of Test Data Description of Test Limit
0 $01 Multiplied by 0.0078 (no dimension) Catalyst deterioration level (bank 1): Determined by waveforms of HO2S 1 and 2 Malfunction criteria for catalyst deterioration
Fig 1: TID $02 EVAP System - Vacuum Monitor
G02645722Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002