Typical Enabling Conditions
ENABLING CONDITIONS
| The monitor will run whenever the following DTCs are not present | See LIST OF DISABLE A MONITOR |
| Battery voltage | 11.5 V or more |
| Intake air temperature | -10°C(14°F)or more |
| Idle | OFF |
| Engine speed | Less than 3,200 rpm |
| Engine coolant temperature | 75°C(157°F)or more |
| Estimated catalyst temperature conditions are met: | 1 & 2 |
| 1. Upstream estimated catalyst temperature | Less than 800°C (1,508°F), and 430 °C (806 °F) or more |
| 2. Downstream estimated catalyst temperature | Less than 675°C (1,292°F), and 290 °C (554 °F) or more |
| Fuel system status | Closed-loop |