LEMON Manuals: Even more car manuals for everyone
Home >> Toyota >> 2003 >> Prius >> Repair and Diagnosis >> Electrical >> Charging Systems >> HV Battery Control System - Diagnostics >> Circuit Inspection >> DTC P3115: HV Battery Current Sensor Malfunction >> Inspection Procedure

Inspection Procedure

  1. Are there any other codes (besides DTC P3115) being output? 

    YES: Go to relevant DTC chart. 

    NO: Go to next step 

  2. Check for open and short in wire harness between battery ECU terminals (V+, IB, V-) and system main relay terminals (6, 7, 2). 

    PREPARATION: 

    1. Disconnect the connector from the battery ECU.
    2. Disconnect the connector from the system main relay.

    CHECK: 

    Confirm the wire harness between the battery ECU and the system main relay is not shorted or open.

    OK: 

    No short and open 

    NG: Repair or replace the wire harness. 

    OK: Go to next step 

  3. Check resistance of HV battery current sensor (In system main relay). 

    CHECK: 

    Using an ohmmeter, measure the resistance between terminals.

    OK: 

    Fig 1: Identifying HV Battery Current Sensor Terminals
    G02829929Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

    Standard resistance: 

    HV BATTERY CURRENT SENSOR TERMINALS RESISTANCE SPECIFICATIONS

    Terminal No. (Tester+) Terminal No. (Tester-) Resistance
    6 7 30 - 50 kΩ
    6 2 More than 10 MΩ
    7 6 30 - 50 kΩ
    7 2 More than 10 MΩ
    2 6 300 - 400 kΩ
    2 7 3 - 5 MΩ

    NG: Replace the system main relay. 

    OK: Check fitting of connector S8 of system main relay and correct if necessary.