Air Induction System: Turbocharger: Inspection
- Using finger pressure on impeller shaft, ensure turbine wheel/shaft assembly turns smoothly. If impeller wheel will not turn or drags when turned, replace turbocharger assembly.
- To check axial shaft play, mount dial indicator to turbo and place dial indicator needle on shaft end. Axial (forward-and-backward) shaft play should be .0051" (.13 mm) or less. If play is not as specified, replace turbocharger.
- To check radial shaft play, insert dial indicator needle into turbo oil outlet hole and into hole in spacer bearing to touch impeller shaft. Set dial indicator against center of impeller shaft. Radial (up-and-down) play should be .0071" (.18 mm) or less. If play is not as specified, replace turbocharger.