LEMON Manuals: Even more car manuals for everyone
Home >> Subaru >> 2006 >> Outback R >> Repair and Diagnosis >> Electrical >> Gauges >> Instrumentation/Driver Information >> Combination Meter System >> Inspection >> Check Power Supply And Ground Circuit

Check Power Supply And Ground Circuit

DIAGNOSIS PROCEDURE

Step Check Yes No
1 CHECK POWER SUPPLY FOR COMBINATION METER. 
  1. Remove the combination meter. < Ref. to REMOVAL , Combination Meter. >
  2. Disconnect the combination meter harness connector.
  3. Turn the ignition switch to ON.
  4. Measure the voltage between combination meter connector and chassis ground.

    Connector & terminal 

    (HO) No. 3, 4 (+) - Chassis ground (-): 

Is the voltage more than 10 V? Go to step 2  . Check the harness for open or short between the ignition switch and combination meter.
2 CHECK POWER SUPPLY FOR COMBINATION METER. 
Measure the voltage between combination meter connector and chassis ground.
Connector & terminal 
(HO) No. 1, 2 (+) - Chassis ground (-): 
Is the voltage more than 10 V? Go to step 3  . Check the harness for open or short between the fuse and combination meter.
3 CHECK GROUND CIRCUIT OF COMBINATION METER. 
  1. Turn the ignition switch to OFF.
  2. Measure the resistance of harness between combination meter connector and chassis ground.

    Connector & terminal 

    (HO) No. 11, 12 - Chassis ground: 

Is the resistance less than 10 Ω? Replace the meter case assembly. Repair the wiring harness.