LEMON Manuals: Even more car manuals for everyone
Home >> Subaru >> 2000 >> Forester L F4-2.5L SOHC >> Repair and Diagnosis >> Starting and Charging >> Battery >> Service and Repair >> Removal and Installation

Removal and Installation




1. Disconnect the positive (+) terminal after disconnecting the negative (-) terminal of battery.
2. Remove flange nuts from battery rods and take off battery holder.
3. Remove battery.
4. Installation is in the reverse order of removal.

Tightening torque:
3.4 ± 1.0 N.m (0.35 ± 0.1 kg.m, 2.5 ± 0.7 ft.lb)

NOTE:
- Clean battery cable terminals and apply grease to retard the formation of corrosion.
- Connect the positive (+) terminal of battery and then the negative (-) terminal of the battery.