Circuit/System Testing
- Ignition OFF. Disconnect the harness connectors at the SDM.
- Verify that there is less than 3.0 Ω between the ground circuit terminal 16 X2 and ground
- If greater than the specified value, test the ground circuit for an open/high resistance.
- Ignition ON, verify a test lamp illuminates between the ignition 1 voltage circuit terminal 29 X2 and ground
- If test lamp did not illuminate, test the ignition 1 voltage circuit for a short to ground or an open/high resistance.
- If all the circuits test normal, replace the SDM.
CAUTION:
Refer to SIR Service Precautions
.