Circuit/System Testing
- Ignition OFF. Disconnect the generator harness connector.
- With the ignition ON, and the engine OFF, connect a test lamp to battery positive voltage and repeatedly probe the generator field duty cycle circuit, harness side, while monitoring the GEN-F Terminal Signal Parameter in the ECM data list with a scan tool. Verify that the scan tool parameter changes from 0 percent to greater than 95 percent.
- If the GEN-F Terminal Signal scan tool parameter was not affected by the test lamp, then test the GEN-F Terminal Signal circuit for a short to voltage, a short to ground, a high resistance, an open circuit. If the circuit tests normal, then replace the ECM.
- If the circuit tests normal during the Ignition ON / Run tests, and the scan tool parameter changed from 0 percent to greater than 95 percent, then replace the generator.