Charge Air Bypass Valve: 4-Cyl
- Disconnect the vacuum hose from the bypass valve. See Fig 1.
- Connect Pressure/Vacuum Pump (30 14 883) and create a negative pressure in the valve.
- Make sure the diaphragm is undamaged. If it is, it will not hold the vacuum.
- Repeat steps 2 and 3 , this time creating positive pressure. See Fig 2.
- Disconnect the pump.
- Connect the vacuum hose.