Circuit/System Testing
- Ignition OFF, disconnect the horn relay.
- Ignition ON, very that a test lamp does not illuminate between the coil control circuit terminal and ground.
- If the test lamp illuminates, test the control circuit for a short to voltage.
- Verify that a test lamp illuminates between the coil side B+ circuit terminal and ground.
- If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance. If the circuit tests normal and the HORN fuse is open, test the horn control circuit terminal for a short to ground. If the circuit tests normal, test or replace the HORN relay.
- Verify that a test lamp illuminates between the switch side B+ circuit terminal and ground.
- If the test lamp does not illuminate, test the switch side B+ circuit for an open/high resistance.
- Ignition OFF, disconnect the harness connector at the horn assembly.
- Test for less than 1.0 ohm of resistance between the horn ground circuit terminal A and ground.
- If greater than the specified range, test the ground circuit for an open/high resistance.
- Connect the harness connector at the horn assembly.
- Connect a 10A fused jumper wire between the switch side B+ circuit terminal and the horn control circuit terminal. Verify the horn is activated.
- If the horn does not activate, test the horn control circuit for an open/high resistance. If the circuit tests normal, test or replace the horn assembly.
- Disconnect the harness connector C2 at the steering wheel.
- Test for less than 1.0 ohm of resistance between the horn switch ground circuit terminal A and ground.
- If greater than the specified range, test the ground circuit for an open/high resistance.
- Connect the harness connector C2 at the steering wheel.
- Ignition ON, Connect a test lamp between the coil side B+ circuit terminal and the coil control circuit terminal.
- Depress the horn pad. The test lamp should turn ON and OFF when pressing and releasing the horn pad.
- If the test lamp is always ON, test the coil control circuit for a short to ground. If the circuit tests normal, replace the horn switch.
- If the test lamp is always OFF, test the control circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the horn switch.
- Command the horn ON and OFF with a scan tool. The test lamp should turn ON and OFF when changing between the commanded states.
- If the test lamp is always OFF, replace the BCM.
- If all circuits test normal, test or replace the HORN relay.