Circuit/System Testing
- Ignition OFF, disconnect the horn relay.
- Ignition ON, verify that a test lamp does not illuminate between the control circuit terminal and ground.
- If the test lamp illuminates, test the control circuit for a short to voltage.
- Verify that a test lamp illuminates between the B+ circuit terminal and ground.
- If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance. If the circuit tests normal and the B+ circuit fuse is open, test the control circuit terminal for a short to ground. If the circuit tests normal, test or replace the horn relay.
- Connect a test lamp between the B+ circuit terminal and the relay control circuit terminal.
- Command the horn output ON and OFF using a scan tool. The test lamp should turn ON and OFF when changing between the command states.
- If the test lamp is always ON, test the control circuit for a short to ground. If the circuit tests normal, replace the BCM.
- If the test lamp is always OFF, test the control circuit for a short to voltage, or an open/high resistance. If the circuit tests normal, replace the BCM.
- If all circuits test normal, test or replace the Horn Relay.