Installation Procedure
Courtesy of GENERAL MOTORS CORP.
- Position and install the fuel feed pipe to the vehicle.
- Install the fuel feed pipe to the retaining clips at the left rear floor panel tunnel brace.
- Close the retaining clips.
Courtesy of GENERAL MOTORS CORP.
- Connect the fuel feed pipe (2) quick connect fitting at the fuel tank feed pipe. Refer to Quick Connect Fitting(s) Service (Plastic Collar) .
Courtesy of GENERAL MOTORS CORP.
- Install the fuel feed pipe to the retaining clips along the floor panel.
- Close the pipe retaining clips.
- Lower the vehicle.
Courtesy of GENERAL MOTORS CORP.
- Install the fuel feed and EVAP pipe clip to the oil level indicator tube bracket.
Courtesy of GENERAL MOTORS CORP.
- Remove the caps or plugs from the fuel pipe and the fuel rail.
- Connect the fuel feed pipe (2) to the fuel rail. Refer to Quick Connect Fitting(s) Service (Metal Collar) .
- Connect the negative battery cable. Refer to Battery Negative Cable Disconnect/Connect Procedure
.
- Inspect for fuel leaks using the following procedure:
- Turn ON the ignition, with the engine OFF for 2 seconds.
- Turn OFF the ignition for 10 seconds.
- Turn ON the ignition, with the engine OFF.
- Inspect for fuel leaks.