The GEN IV V8 engine is fitted with a Mitsubishi 140 amp generator. This generator is mounted on the lower, left-hand side of the engine. It has an internally mounted regulator, a single lower mounting lug and no external cooling fans.

The generator is 3 phase, incorporating a rotor with 6 pole pairs and 2 (internal) cooling fans, one on the drive end and one on the slip-ring end. The rotor is supported by ball bearing races in both the drive and slip-ring end housings. The stator surrounds the rotor and has a 3-phase delta connected output winding on a ring shaped lamination pack.

The output of the stator winding is rectified by 6 diodes within the slip-ring end housing. Excitation current is supplied to the rotor field coil via the voltage regulator, the brushes and slip-rings. The electronic voltage regulator requires no adjustment in service.

The generator has 2 external connections: