Code 42, Electronic Spark Timing (Est)
The ignition module sends a reference signal on circuit No. 430 to ECM when the engine is cranking. While engine speed is under 400 RPM, the the ignition module controls ignition timing. When engine speed exceeds 400 RPM, ECM applies 5 volts to the by-pass line, circuit No. 424, to switch the timing to ECM control circuit No. 423.
When engine RPM is below 400, the ignition module grounds the EST signal. If the ECM detects voltage on the EST circuit during this condition, ECM sets a Code 42. With engine above 400 RPM, voltage will be applied to by-pass circuit, and EST should no longer be grounded in ignition module.
If by-pass circuit is open or grounded, a Code 42 will set. If EST circuit is grounded, a Code 42 will set.
NOTE:
Test numbers refer to test numbers on diagnostic chart.
- Code 42 means ECM has detected an open or short to ground in EST or by-pass circuits. This test confirms Code 42 and the fault causing the code is present.
- Check for a normal EST ground path through ignition module. An EST circuit No. 423 shorted to ground will also read less than 500 ohms.
- As the test light voltage touches circuit No. 424, the module should switch, causing the ohmmeter to read above 5000 ohms. Ensure module switched, causing ohms to increase.
- If the module did not switched in this test, check for:
- EST circuit No. 423 shorted to ground.
- By-pass circuit No. 424 open.
- Faulty ignition module connection or module.
- Confirms Code 42 is faulty ECM and not an intermittent in circuits No. 423 or 424.