Chart C-1A, Park/Neutral Switch
The Park/Neutral switch contacts are closed to ground in Park or Neutral, and open in all other ranges. The ECM supplies ignition voltage through a current limiting resistor to circuit No. 434, and senses a closed switch when voltage in circuit No. 434 drops to less than one volt. The ECM uses the Park/Neutral switch signal as one of the inputs to control idle air control and spark timing.
NOTE:
Test numbers refer to test numbers on diagnostic chart.
- Checks for a closed switch to ground in Park position. Different makes of "Scan" testers will read value differently. Refer to tester operation manual for type of display used.
- Checks for an open switch in Drive range.
- Be sure "Scan" tester indicates drive, even while wiggling shifter to test for an intermittent or misadjusted switch in Drive range.