Rotor Assembly Test
Check field slip rings for excessive wear or roughness. Using a volt/ohmmeter, test for continuity from one slip ring to the other. Test should show a closed circuit. Using a volt/ohmmeter, test for continuity from both field coil slip rings to rotor shaft or core. Test should show open circuit. If failure is detected in either test, replace rotor assembly.