Centrifugal Advance Curve Check
Install distributor in test stand. It is important that appropriate adapter for checking electronic type distributors is used. Adjust tester speed control to operate distributor at speeds called for in Distributor Advance Specifications Tables. If advance is not according to specifications, replace distributor shaft assembly (shaft, reluctor, weights, etc.).