DTC 74: PMV Pressure Switch Open Or Shorted
NOTE:
To identify circuits and terminals referenced in text and flowcharts, see Figure
.
Pressure switch monitors primary brake system pressure. Normally closed switch opens when brakes are applied and pressure exceeds 101 psi (7 kg/cm2 ). If brakes are manually applied during traction control mode, PMV pressure switch input, along with brake switch input, signal the EBTCM to disable traction control and allow manual braking. Pressure switch is part of the PMV assembly and is not serviceable.
DTC 74 will set when EBTCM detects an open in circuit No. 853 or 1659, a short to ground in circuit No. 1659 with brakes applied, or a failed PMV pressure switch.