Circuit Description
When ignition switch is first turned to RUN position, EBCM/EBTCM goes through a self-test, which lasts 2-4 seconds. During self-test, EBCM/EBTCM grounds terminal No. 52, causing Amber ANTI-LOCK warning light to illuminate.
EBCM/EBTCM also grounds terminal No. 34, energizing main relay and removing warning light ground path provided through anti-lock diode and main relay contacts. When self-test is completed and no faults are detected, EBCM/EBTCM removes ground at terminal No. 52, turning off warning light. Main relay remains energized.
When EBCM/EBTCM detects a fault, it grounds terminal No. 52, causing Amber ANTI-LOCK warning light to illuminate. EBCM/EBTCM will also de-energize main relay, creating a redundant ground path. If EBCM/EBTCM is disabled for any reason, main relay will be de-energized. This provides ANTI-LOCK warning light ground path through anti-lock diode and main relay contacts, causing warning light to illuminate with no DTCs being set.