Chart C-12, Cooling Fan Circuit Diagnosis: Notes
Cooling fan is controlled by Powertrain Control Module (PCM) based on inputs from Engine Coolant Temperature (ECT) sensor, Intake Air Temperature (IAT) sensor, A/C control switch, A/C refrigerant pressure sensor and Vehicle Speed Sensor (VSS). PCM grounds circuit No. 335, energizing cooling fan relay and turning on cooling fan. Cooling fan is turned on when engine coolant temperature is greater than 217°F (103°C), A/C clutch is requested or vehicle speed is less than 35 MPH. If Diagnostic Trouble Code (DTC) 14 or 15 is set, engine coolant temperature is greater than 239°F (115°C) or A/C refrigerant pressure is high, fan relay is energized regardless of vehicle speed.
Under certain high temperature conditions, cooling fan will continue to run for up to 7 minutes after ignition is off. Fan run-on occurs when ECT sensor indicates greater than 212°F (100°C) and IAT sensor indicates greater than 176°F (80°C); ECT sensor indicates greater than 234°F (112°C) and IAT sensor indicates greater than 158°F (70°C); or ECT sensor indicates greater than 241°F (116°C).
- With fan relay activated, cooling fan driver should close, energizing cooling fan relay.
- Tests if fault is in wiring or fan relay connection.