Chart A, Loss Of IPC Display (Non-CRT Equipped)
Loss of IPC display and messages can result from following:
- Loss of 12-volt power to IPC.
- Loss of ground to IPC.
- Loss of wake-up signal to BCM.
- Internal fault in BCM or IPC.NOTE: Test numbers refer to numbers on diagnostic chart.
- This step checks to see if BCM is functioning.
- This step checks BCM power and ground sources.
- This step checks to see if IPC has lost power or ground. Normally with ignition on, battery voltage should be present at listed terminals.
- This step checks for short to ground in any 640 circuit.
- This step checks if short to ground is inside component or in circuit.
- This step checks if IPC is receiving wake-up signal from BCM.