DTC P0582: Speed Control Vacuum Control Circuit: Notes
For a complete wiring diagram, refer to SYSTEM WIRING DIAGRAMS .
- When Monitored:
Ignition on and battery voltage greater than 10 volts .
- Set Condition:
An open or shorted condition detected in the Speed control vacuum solenoid control circuit. One Trip Fault. Three good trips to turn off the MIL .
Possible Causes
(V32) S/C SUPPLY CIRCUIT OPEN
(V32) S/C SUPPLY SHORT TO GROUND
(V36) S/C VACUUM SOL CONTROL CIRCUIT SHORTED TO GROUND
(V36) S/C VACUUM SOL CONTROL CIRCUIT OPEN
(Z155) GROUND CIRCUIT OPEN
SPEED CONTROL VACUUM SOLENOID
PCM