DTC P0462: Fuel Level Sensor 1 Circuit Low: Notes
For a complete wiring diagram, refer to SYSTEM WIRING DIAGRAMS .
- When Monitored:
Ignition on and battery voltage above 10.4 volts .
- Set Condition:
The fuel level sensor signal voltage goes below 0.4 of a volt for more than 90 seconds. One Trip Fault. Three good trips to turn off the MIL .
Possible Causes
(N4) FUEL LEVEL SIGNAL CIRCUIT SHORTED TO GROUND
(N4) FUEL LEVEL SIGNAL CIRCUIT SHORTED TO THE (N5) FUEL LEVEL SENSOR RETURN CIRCUIT
FUEL LEVEL SENSOR
INSTRUMENT CLUSTER
Always perform PRE-DIAGNOSTIC TROUBLESHOOTING PROCEDURE before proceeding.