LEMON Manuals: Even more car manuals for everyone
Home >> Mitsubishi >> 2006 >> Raider XLS, RWD >> Repair and Diagnosis >> Engine Performance >> System >> Electrical Diagnostics (2 Of 5) >> DTC P0139: O2 Sensor 1/2 Slow Response >> Theory of Operation

Theory of Operation

The downstream O2 Sensor is located in the exhaust path behind the catalytic converter, is monitored for proper response to assure optimum catalytic converter efficiency. The downstream O2 response monitor is intended to diagnose a downstream O2 sensor that is not moving or stuck in a voltage window and to insure accurate information for catalyst monitor diagnosis.

Possible Causes 

EXHAUST LEAK

(K141) O2 1/2 SIGNAL CIRCUIT

(K904) O2 RETURN DOWNSTREAM CIRCUIT

O2 SENSOR

Always perform  PRE-DIAGNOSTIC TROUBLESHOOTING PROCEDURE  before proceeding.