Turbocharger Bypass Valve Check
- Remove the turbocharger bypass valve.
- Connect the hand vacuum pump to the nipple of the turbocharger bypass valve.
- Apply a negative pressure of approximately 53 kPa (16 in.Hg) and check operation of the valve. Also check that air tightness is maintained.
Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.