LEMON Manuals: Even more car manuals for everyone
Home >> Mitsubishi >> 2003 >> Lancer Evolution >> Repair and Diagnosis >> Engine Mechanical >> Intake And Exhaust - Evolution >> On-Vehicle Service >> Turbocharger Bypass Valve Check

Turbocharger Bypass Valve Check

  1. Remove the turbocharger bypass valve.
  2. Connect the hand vacuum pump to the nipple of the turbocharger bypass valve.
  3. Apply a negative pressure of approximately 53 kPa (16 in.Hg) and check operation of the valve. Also check that air tightness is maintained.
    Fig 1: Turbocharger Bypass Valve Check Reference Table
    G01869517Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.
    Fig 2: Checking Turbocharger Bypass Valve
    G01869518Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.