Input Signal
NOTE:
If after all testing has been completed, power mirror is still not functioning, substitute ETACS unit with known good unit and retest.
- Access Data Link Connector (DLC) at lower left corner of dash. Using Special Tool (MB991529), connect positive lead of analog voltmeter to terminal No. 9 and negative lead to terminal No. 4 or 5. SeeFig 1 . Check if input signals from power mirror switch are being received by ETACS module.
- Voltmeter needle should sweep when each switch is operated. If switch or related component is not functioning, voltmeter will not operate when switch is activated. Check related circuit and/or component.