Communication Fault For Electric Fan (SI M12 07 16)
Reference number: SI M12 07 16
COMMUNICATION FAULT FOR ELECTRIC FAN
TECHNICAL SERVICE BULLETIN
| MINI: | F56 (Hardtop); F55 (Hardtop 4 Door); Produced to October 31, 2015 |
| GROUP: | Engine Electrical Systems |
SITUATION
The Service Engine Soon light is on with the following fault code stored in the DME:
- 1A2005 - electric fan: Communication fault
CAUSE
DME software calibration
CORRECTION
Update the DME with the latest version of ISTA/P.
PROCEDURE
Program the vehicle using the latest version of ISTA/P (3.59.0 or higher).
Target integration level: F056-15-11-500 or higher
For information on programming and coding with ISTA/P, refer to CenterNet/Aftersales Portal/Service/Workshop Technology/Vehicle Programming.
Always connect a MINI approved battery charger/power supply (SI M04 08 09 ).
WARRANTY INFORMATION
Covered under the terms of the MINI New Passenger Car Limited Warranty or the MINI NEXT Certified Pre-Owned Limited Warranty.
| Defect Code: | 1711119900 | |
|---|---|---|
| Labor Operation: | Labor Allowance: | Description: |
| 00 00 006 | Refer to KSD2 | Performing "vehicle test" (with vehicle diagnosis system - checking faults) (Main work) |
| Or: | ||
| 00 00 556 | Refer to KSD2 | Performing "vehicle test" (with vehicle diagnosis system - checking faults) (Plus work) |
| And: | ||
| 61 21 528 | Refer to KSD2 | Connect an approved battery charger/power supply (indicated in KSD 2 as Charging battery) |
| And: | ||
| 61 00 730 | Refer to KSD2 | Programming/encoding control unit(s) |
If you are using a Main labor code for another repair, use the Plus code labor operation 00 00 556 instead.
Refer to KSD2 for the corresponding flat rate unit (FRU) allowances.
Vehicle Programming and Coding
When ISTA/P automatically reprograms and codes all the vehicle control modules that currently do not have the latest software and control module failures occur during this programming:
- Please claim these consequential control module repair work under the defect code listed in this bulletin with the applicable KSD2 labor operations.
Other Repairs
Control module failures that occurred prior to this programming:
- When covered under an applicable limited warranty, claim these control module repairs using the applicable defect code and labor operations in KSD2.