Service Campaign 2021020001 - Update Supplemental Restraint System (SRS) Control Unit Software (P-SC-2021020001)

Publication date: 2021-03-05
Reference number: P-SC-2021020001
Supersedes refnos: 2021020001

SERVICE CAMPAIGN 2021020001 - UPDATE SUPPLEMENTAL RESTRAINT SYSTEM (SRS) CONTROL UNIT SOFTWARE

SERVICE CAMPAIGN 2021020001 - UPDATE SUPPLEMENTAL RESTRAINT SYSTEM (SRS) CONTROL UNIT SOFTWARE

SERVICE CAMPAIGN BULLETIN

Reference Number(s): P-SC-2021020001, Date of Issue:  March 05, 2021
MERCEDES-BENZ: MY20-21 167 (GLE-Class, GLS-Class)

SERVICE INFORMATION

IMPORTANT NEW SERVICE CAMPAIGN LAUNCH INFORMATION 

Please note that all customer inquiries should be directed to the Customer Assistance Center at 1-800-FOR-MERCEDES.

Sincerely,

Gregory Gunther

Department Manager, Vehicle Compliance & Analysis

G13612306

TO: ALL MERCEDES-BENZ CENTERS

SUBJECT

Models GLE-Class, GLS-Class (217 platform) 

Model Year 2020-2021 

Mercedes-Benz AG ("MBAG"), the manufacturer of Mercedes-Benz, has determined that on certain Model Year ("MY") 2020-2021 GLE-Class and GLS-Class (167 platform) vehicles, the supplemental restraint system ("SRS") control unit software does not correspond to the current production specifications. All regulatory specifications are nevertheless met and a potential safety relevance can be ruled out. An authorized Mercedes-Benz dealer will update the SRS control unit software.

Prior to performing this Service Campaign:

Approximately 17,591 vehicle is affected.

Order No. P-SC-2021020001

This bulletin has been created and maintained in accordance with MBUSA-SLP S423QH001, Document and Data Control, and MBUSA-SLP S424HH001, Control of Quality Records.

NOTE:
  • Use Xentry 12/20 with all associated patches or higher.
  • Follow the steps exactly as described in Xentry.
  • Connect battery charger (battery voltage >12.5V).
  • Ensure all electrical consumers are switched-off.
  • In the event of software/SCN update issues, contact Star Diagnosis User Help Desk via. XSF ticket.
  • Refer to Star Diagnosis System (SDS) Best Practices Guide.

PROCEDURE

  1. Connect XENTRY Diagnosis.
  2. Update Supplemental Restraint System (SRS) control unit software.

    To do this, select menu item "Quick test view → N2/10 Supplemental Restraint System (SRS)  → Adaptations → Configuration → Manual Settings → Check control unit software → Action 1380 2020 0296  ".

    Then follow the user guidance in XENTRY Diagnosis.

WARRANTY INFORMATION

Operation:  Connect/disconnect battery charger (02-5058)

Star Diagnosis System (SDS), Connect/disconnect (02-4762)

Update Supplemental Restraint System (SRS) control unit software. (02-9334)

WARRANTY INFORMATION

Damage Code Operation Number Labor Time (hrs.)
54 975 19 8 02-5058(1) 0.1
02-4762(1) 0.1
02-9334 0.1
(1) Operation item may be invoiced only once for each workshop order
NOTE: Operation Number labor times are subject to change