LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 2006 >> R500 >> Repair and Diagnosis >> Engine Performance >> Ignition System >> Mixture Formation -- R500 >> Basic Knowledge >> ME-SFI limiting maximum engine speed - function - GF07.61-P-3007BK

ME-SFI limiting maximum engine speed - function - GF07.61-P-3007BK

ENGINE 113.967 in MODEL 219 

ENGINE 113.964 in MODEL 164.1 up to Model Year 8 

ENGINE 113.971 in MODEL 251 up to Model Year 8 

Fig 1: ME-SFI Limiting Maximum Engine Speed Function Diagram
G07302055Courtesy of MERCEDES-BENZ USA

The ME-SFI control unit detects the engine speed from the signal supplied by the crankshaft position sensor. As a protection for the engine and the drive train, engine speed is limited by retarding the ignition timing and switching off the fuel injection valves if the following conditions exist:

  1. Transmission overload protection 
    1. 1.1 Torque converter protection of automatic transmission 

      In order to protect the torque converter in selector lever positions P and N (no power flow) from excessive static internal pressure, engine speed is limited to approx. 4200 RPM.

    2. 1.2 Manual transmission (no gear engaged) 

      In order to avoid damage to the transmission engine speed is limited to approx. 4000 RPM.

  2. Limiting maximum engine speed when driving 

    The engine speed is limited to 6000 RPM in order to protect the engine from the consequences of impermissibly high speeds. The driving mode is detected from the vehicle speed signal.

  3. Throttle valve actuator defective 

If the throttle valve actuator is faulty, the engine speed in neutral is restricted to approx. 1400 RPM and in driving mode to approx. 1800 RPM.

  Component description for the engine electronics control unit   GF07.61-P-6000BK 
  Component description for the crankshaft position sensor   GF07.04-P-6010BK 
  ME-SFI safety fuel shutoff - function   GF07.61-P-3018BK 
  Component description for the throttle valve actuator   GF30.20-P-2020BK