Shows model 219 

Fig 1: ME-SFI TWC Heating-Up Function Diagram
G07302069Courtesy of MERCEDES-BENZ USA

The TWC heating-up function heats up the catalytic converters more rapidly to their operating temperature (300 to 450°C) and thus considerably reduces the exhaust emissions in the cold start and heating-up phase.

The ME control unit is able to detect that the operating temperature has been reached and that the catalytic converters are operating at normal efficiency from the signals supplied by the O 2 sensor signals.

The following conditions determine whether TWC heating is enabled:

The following systems are involved in the TWC heating-up:

  Component description for the engine electronics control unit   GF07.61-P-6000BK 
  Component description for the O 2 sensor   GF07.04-P-6100BK 
  Component description for the crankshaft position sensor   GF07.04-P-6010BK 
  Component description for the throttle valve actuator   GF30.20-P-2020BK
  Component description for the coolant temperature sensor   GF07.04-P-6040BK 
  Component description for the hot film MAF sensor   GF07.07-P-6000BK 
  Component description for the air pump switchover valve   GF14.30-P-2020BK
  Component description for the electric air pump   GF14.30-P-2000BK
  Component description for the aspirator shutoff valve with integral check valve   GF14.30-P-2100BK
  Component description for the pressure sensor   GF07.04-P-6060BK 
  Component description for the ignition coil   GF15.10-P-2100BK
  Component description for the three-way catalytic converter   GF49.10-P-2010BK