Diagnostic Procedure
| STEP | INSPECTION | RESULTS | ACTION |
|---|---|---|---|
| 1 | INSPECT COOLING SYSTEM FOR MALFUNCTION
|
Yes | Go to the next step. |
| No | ECT PID is higher than 112 °C {233 °F}
:
ECT PID is less than 82 °C {180 °F} :
|
||
| 2 | VERIFY PCM DTC
|
Yes | Go to the appropriate DTC inspection. (See DTC TABLE .) |
| No | Go to the next step. | ||
| 3 | VERIFY CURRENT INPUT SIGNAL STATUS
|
Yes | Go to the next step. |
| No | AC_REQ PID is not specified:
COLP PID is not specified:
CPP PID is not specified:
CPP/PNP PID:
PSP PID:
TR PID:
Repair or replace the malfunctioning part according to the inspection results. |
||
| 4 | INSPECT INTAKE AIR SYSTEM FOR AIR LEAKAGE
|
Yes | Repair or replace the malfunctioning part according to the inspection results. |
| No | Inspect the following:
Repair or replace the malfunctioning part according to the inspection results. |
||
| 5 |
|
||