Diagnostic Monitoring Test Results
- The purpose of this test mode is to confirm the result of OBD-II monitor diagnostic test results. The result values stored when particular monitor is completed are displayed. If the monitor is not completed, initial value is displayed.
DIAGNOSTIC MONITORING TEST RESULTS (MZR 1.5)
| OBD Monitor ID | Test ID | Description | Related system | Scaling ID | Unit |
|---|---|---|---|---|---|
| 01 | 80 | A/F sensor lean-to-rich response time (calculated) | A/F sensor, HO2S | 20 | Ratio |
| 01 | 81 | A/F sensor rich-to-lean response time (calculated) | 20 | Ratio | |
| 01 | 82 | A/F sensor lean-to-rich response time (calculated) | 20 | Ratio | |
| 01 | 83 | A/F sensor rich-to-lean response time (calculated) | 20 | Ratio | |
| 02 | 03 | Low HO2S voltage for switch time calculation (constant) | 0A | Voltage | |
| 02 | 04 | High HO2S voltage for switch time calculation (constant) | 0A | Voltage | |
| 02 | 05 | HO2S rich-to-lean response time (calculated) | 10 | Time | |
| 02 | 80 | HO2S response time out (calculated) | 10 | Time | |
| 21 | 80 | A/F sensor and HO2S switching time ratio | Catalyst | 20 | Ratio |
| 31 | 83 | EGR pressure variation | EGR | 17 | Pressure |
| 35 | 80 | Over - retarded | Variable valve timing | 9C | deg.CA |
| 35 | 81 | Over - advanced | Variable valve timing | 9C | deg.CA |
| 3A | 80 | Phase 0 end pressure result and test limits | EVAP system | FE | Pa |
| 3A | 81 | Phase 4 vapor generation minimum change in pressure and test limits | EVAP system | FE | Pa |
| 3A | 82 | Phase 0 end pressure result and test limits | EVAP system | FE | Pa |
| 3B | 80 | Phase 2 0.040" cruise leak check vacuum bleed-up and test limits | EVAP system | FE | Pa |
| 3C | 81 | EONV positive pressure test result and limits | EVAP system | FE | Pa |
| 3C | 82 | EONV negative pressure (vacuum) test result and limits | EVAP system | FE | Pa |
| 3C | 83 | Normalized average of four EONV tests results and limits | EVAP system | 03 | Raw Value |
| 3D | 80 | Blocked EVAP system line - screening test | EVAP system | A9 | Pa/s |
| 3D | 81 | Blocked EVAP system line - fault confirmation test | EVAP system | FE | Pa |
| A2 | 0B | Cylinder No. 1 average misfire counts for last 10 DC | Misfire | 24 | Counts |
| A2 | 0C | Cylinder No. 1 misfire counts for last/current DC | 24 | Counts | |
| A3 | 0B | Cylinder No. 2 average misfire counts for last 10 DC | 24 | Counts | |
| A3 | 0C | Cylinder No. 2 misfire counts for last/current DC | 24 | Counts | |
| A4 | 0B | Cylinder No. 3 average misfire counts for last 10 DC | 24 | Counts | |
| A4 | 0C | Cylinder No. 3 misfire counts for last/current DC | 24 | Counts | |
| A5 | 0B | Cylinder No. 4 average misfire counts for last 10 DC | 24 | Counts | |
| A5 | 0C | Cylinder No. 4 misfire counts for last/current DC | 24 | Counts |