DTC P2006 (L3) DIAGNOSTIC PROCEDURE
| STEP | INSPECTION | ACTION | |
|---|---|---|---|
| 1 | VERIFY FREEZE FRAME DATA HAS BEEN RECORDED
|
Yes | Go to the next step. |
| No | Record the FREEZE FRAME DATA on repair order, then go to the next step. | ||
| 2 | VERIFY RELATED REPAIR INFORMATION AVAILABILITY
|
Yes | Perform repair or diagnosis according to the available repair information.
|
| No | Go to the next step. | ||
| 3 | CLASSIFY INTERMITTENT CONCERN OR CONTINUOUS CONCERN
|
Yes | Go to the next step. |
| No | Intermittent concern exists. Go to INTERMITTENT CONCERN TROUBLESHOOTING procedure. (See INTERMITTENT CONCERN TROUBLESHOOTING [L3] .) |
||
| 4 | INSPECT VARIABLE TUMBLE SHUTTER VALVE SWITCH CONNECTOR AND VARIABLE TUMBLE SOLENOID VALVE CONNECTOR FOR POOR CONNECTION
|
Yes | Repair or replace the terminal, then go to Step 12. |
| No | Go to the next step. | ||
| 5 | INSPECT VARIABLE TUMBLE SHUTTER VALVE ACTUATOR
|
Yes | Go to the next step. |
| No | Repair or replace malfunctioning part according to inspection results, then go to Step 8. | ||
| 6 | INSPECT VARIABLE TUMBLE SOLENOID VALVE OR VARIABLE TUMBLE SHUTTER VALVE SWITCH SIGNAL CIRCUIT FOR SHORT TO GROUND
|
Yes | Repair or replace the wiring harness for a short to ground, then go to Step 8. |
| No | Go to the next step. | ||
| 7 | INSPECT PCM CONNECTOR FOR POOR CONNECTION
|
Yes | Repair the terminal, then go to Step 12. |
| No | Go to the next step. | ||
| 8 | VERIFY TROUBLESHOOTING OF DTC P2006 COMPLETED
|
Yes | Replace the PCM, then go to the next step. (See PCM REMOVAL/INSTALLATION [L3] .) |
| No | Go to the next step. | ||
| 9 | VERIFY AFTER REPAIR PROCEDURE
|
Yes | Go to the applicable DTC troubleshooting. (See DTC TABLE [L3] .) |