Throttle Opener Adjustment
- Install tachometer on engine and set idle speed to 800 RPM. Stop Engine and disconnect vacuum sensing tube between servo diaphragm and vacuum control valve. Disconnect at servo diaphragm.
- Remove intake manifold suction hole plug and connect intake manifold and servo diaphragm with suitable length of tubing. Start engine and read engine speed. If speed is 1400 ± 100 RPM, the servo diaphragm is normal.
- When speed is lower than specified, turn adjusting screw clockwise,- when higher, turn adjusting screw counterclockwise. Reconnect components in original orders and install a vacuum gauge to the intake manifold.
- Start engine and raise engine speed to 3000 RPM. Release throttle to allow RPM to drop suddenly. Adjust vacuum control valve adjusting screw so that when engine speed descends from 3000 RPM to 1000 RPM, the vacuum reading will be above 22" of mercury. The needle on the gauge should remain stationary for a few seconds at this reading and then fall.