Normal Operation and Fault Conditions
The ABS module monitors various inputs and compares the values to what should be expected. If the values received are out of range or not what should be expected, the ABS module sets a DTC.
PPT AO ABS MODULE DTC FAULT TRIGGER CONDITIONS
| DTC | Description | Fault Trigger Conditions |
|---|---|---|
| C0062:76 | Longitudinal Acceleration Sensor: Wrong Mounting Position | Sets when the ABS module detects the RCM is installed in the wrong position. |
Possible Causes
- RCM concern
- AO1: CHECK THE RCM MOUNTING
- Verify the RCM is installed correctly and the fasteners are tightened to specifications.
- Is the RCM mounted correctly?
Yes No CARRY OUT the RCM self-test. DIAGNOSE the DTCs present. REFER to Supplemental Restraint System . Correctly INSTALL the RCM and/or tighten the fasteners to specification. REFER to Supplemental Restraint System .