Heating Characteristics
NOTE:
The presence of overtemp faults (DTCs B2729 and B2730) can be induced by incorrect operation of the climate controlled seat system after an initial HEAT setting has been attained. If a HEAT setting is repeatedly turned OFF and ON in an attempt to increase the seat temperature, an overtemp condition can result and the DTC(s) will be set.
- The climate controlled seat system draws approximately 7.5 amps until reaching the set point, and then the system operates at a reduced amperage to maintain the climate setting.
- In HEAT mode, the TED can add up to 40-60°C (72-108°F) to the ambient air temperature entering the system.
- There are five manual settings based on the position of the climate controlled seat switch on the center console. Position one is the LOW setting and position five is the HIGH setting.
- In the LOW setting, the climate controlled seat module is set to maintain TED temperature at 37°C (99°F).
- In the HIGH setting, the climate controlled seat module is set to maintain TED temperature at 65°C (149°F).
- If the temperature at one of the TEDs rises above 90°C (19°F) in the HEAT mode or 70°C (149°F) in the COOL mode for more than four seconds, the CCSM will record an overtemp DTC, remove power from the TEDs and go into "Blower Only" mode in an attempt to cool down the TEDs. If the TEDs temperature has not dropped to 85°C (185°F) in the HEAT mode or 65°C (140°F) in the COOL mode after 30 seconds, the CCSM will shut down and remain off until the ignition is cycled. Also if the CCSM detects an overtemp twice during the same ignition cycle, it will also shut down.
- In HEAT mode, there is no linear correlation between the seat fan motor speed and the TED supply voltage. The CCSM will independently vary the fan speed and the TED supply voltage in order to reach and maintain the temperature determined by the switch setting.