Door Window Glass
Lower door window glass 3" (76.2 mm) from full up position. Remove door trim panel and watershield. Loosen nuts securing window regulator. Raise door window glass to full up position. Tighten nuts to 80-123 INCH lbs. (9-14 N.m). Install watershield and door trim panel. Open and close window to verify proper operation.