Inspection [07/2015 - ]: Procedure
- INSPECT POWER SWITCH
- Measure the resistance according to the value(s) in the table below.TEXT IN ILLUSTRATION
*a Component without harness connected
(Power Switch)- - Standard Resistance
Tester Connection Condition Specified Condition H44-5 (SS1) - H44-6 (AGND) Not pushed 10 kΩ or higher H44-1 (SS2) - H44-6 (AGND) H44-5 (SS1) - H44-6 (AGND) Pushed Below 1 Ω H44-1 (SS2) - H44-6 (AGND) If the result is not as specified, replace the power switch.
- Apply battery voltage between the terminals of the switch, and check the illumination condition of the power switch.TEXT IN ILLUSTRATION
*a Component without harness connected
(Power Switch)*b Indicator Light HINT:
- If a positive (+) auxiliary battery lead and a negative (-) auxiliary battery lead are incorrectly connected, the power switch indicator light will not illuminate.
- If the voltage is too low, the indicator light will not illuminate.
OK
Measurement Condition Specified Condition Positive (+) auxiliary battery → Terminal H44-9 (SWIL)
Negative (-) auxiliary battery → Terminal H44-6 (AGND)Illuminates If the result is not as specified, replace the power switch.
- Measure the resistance according to the value(s) in the table below.