On-Vehicle Inspection [08/2014 - ]: Procedure
- CHECK AUXILIARY BATTERY
- Check that the auxiliary battery cables are connected to the correct terminals.
If they are not, connect them properly.
- Check the auxiliary battery for damage and deformation. If severe damage, deformation or leakage is found, replace the auxiliary battery.
- Check that the auxiliary battery cables are connected to the correct terminals.
- CHECK AUXILIARY BATTERY VOLTAGE
- Turn the power switch off and turn on the high beam headlights for 30 seconds. This will remove the surface charge from the auxiliary battery.
- Measure the auxiliary battery voltage according to the value(s) in the table below.
Result
Tester Connection Condition Specified Condition Result Positive (+) auxiliary battery terminal - Negative (-) auxiliary battery terminal 20°C (68°F), Power switch off 12.5 V or higher Auxiliary battery is OK 11.0 to 12.5 V Recharge auxiliary battery Below 11.0 V Replace auxiliary battery
- RECHARGE AUXILIARY BATTERY
- Recharge the auxiliary battery.
HINT:
- Recharge the auxiliary battery according to the charger's instructions.
- Apply the appropriate charging current according to the type of auxiliary battery as shown in the table below.
Auxiliary Battery Type Charging Current S46B24R 4 to 5 A - Turn the power switch off and turn on the high beam headlights for 30 seconds. This will remove the surface charge from the auxiliary battery.
- Measure the auxiliary battery voltage according to the value(s) in the table below.
Result
Tester Connection Condition Specified Condition Result Positive (+) auxiliary battery terminal - Negative (-) auxiliary battery terminal 20°C (68°F), Power switch off 12.5 V or higher Auxiliary battery is OK 11.0 to 12.5 V Recharge auxiliary battery Below 11.5 V Replace auxiliary battery
- Recharge the auxiliary battery.
- CHECK AUXILIARY BATTERY TERMINAL, FUSIBLE LINK AND FUSE
- Check that the auxiliary battery terminals are not loose or corroded.
Positive (+) Auxiliary Battery Terminal
Torque: 5.4 N*m (55 kgf*cm, 48 in.*lbf)
Negative (-) Auxiliary Battery Terminal
Torque: 5.4 N*m (55 kgf*cm, 48 in.*lbf)
If the terminals are corroded, clean them.
- Measure the resistance of each fusible link and fuse for the auxiliary battery charging system.
Standard Resistance
Below 1 Ω
If any of the results is not as specified, replace the fusible link or fuse as necessary.
- Check that the auxiliary battery terminals are not loose or corroded.
- CHECK AMD TERMINAL
- Remove the service plug grip. (Refer to Removal [08/2014 - ] )
- Check that the AMD terminal is connected securely, and there is no contact problem.
If there are any arc marks, replace the affected parts.
- Check that the nut for the AMD terminal is tightened to the specified torque.
Torque: 8.3 N*m (85 kgf*cm, 73 in.*lbf)
If there are no arc marks and the AMD terminal connection is faulty, connect the AMD terminal securely.
- Install the service plug grip. (Refer to Installation [08/2014 - ] )
- CHECK DC/DC CONVERTER FUNCTION
- Connect an AC/DC 400 A probe to the positive (+) auxiliary battery cable.TEXT IN ILLUSTRATION
*a Probe Direction *b Current Flowing into Auxiliary Battery - Turn the power switch on (READY) and leave the vehicle as it is until the electric current flowing into the auxiliary battery becomes 10 A or less.
- Turn on the high beam headlights, and turn the blower motor switch to the HI position and the rear window defogger on.
- Measure the current and voltage according to the value(s) in the table below.TEXT IN ILLUSTRATION
*a Probe Direction *b Current Flowing from Auxiliary Battery Result
Item Tester Connection Condition Specified Condition Current flowing from auxiliary battery Positive (+) auxiliary battery cable Power switch on (READY)
(The high beam headlights are on, the blower motor switch is in the HI position, and the rear window defogger is turned on)0 A or less
(no current from auxiliary battery)Auxiliary battery voltage Positive (+) auxiliary battery terminal - Negative (-) auxiliary battery terminal 13 to 15 V HINT:
Some vehicle models have an inverter with converter assembly with a built-in DC/DC converter. In this case, replace the inverter with converter assembly.
If the values are not as specified, replace the DC/DC converter assembly.
- Connect an AC/DC 400 A probe to the positive (+) auxiliary battery cable.