Inspection Procedure
- INSPECT SHIFT LOCK CONTROL ECU
- Disconnect the K39 ECU connector.
- Measure the resistance of the ECU.
Standard resistance
STANDARD RESISTANCE SPECIFICATIONTester Connection Condition Specified Condition 11 (P2) - 8 (E) Shift lever position in P 10 kΩ or higher 11 (P2) - 8 (E) Shift lever position other than P Below 1 Ω
NG: GO TO SHIFT LOCK SYSTEM
OK: GO TO Next Step
- CHECK WIRE HARNESS (POWER SOURCE CONTROL ECU - SHIFT LOCK CONTROL ECU)
- Disconnect the K73 ECU connector.
- Disconnect the K39 ECU connector.
- Measure the resistance of the wire harness side connectors.
Standard resistance
STANDARD RESISTANCE SPECIFICATIONTester Connection Specified Condition K73-5 (P) - K39-11 (P2) Below 1 Ω K73-5 (P) or K39-11 (P2) - Body ground 10 kΩ or higher
NG: REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: GO TO Next Step
- READ VALUE OF INTELLIGENT TESTER (SHIFT P SIGNAL)
- Check the DATA LIST for proper functioning of the shift position signal.
Power source control ECU
POWER SOURCE CONTROL ECU - DATA LIST REFERENCEItem Measurement Item / Display (Range) Normal Condition SHIFT P SIG Shift position signal / ON or OFF ON: Shift position is P
OFF: Shift position is not POK: ON (shift position is P) appears on screen.
NG: GO TO HYBRID CONTROL SYSTEM
OK: REPLACE POWER SOURCE CONTROL ECU
- Check the DATA LIST for proper functioning of the shift position signal.