Component Inspection
TEMPERATURE SENSOR SPECIFICATIONS
| Temperature[°C(°F)] | Resistance [kΩ] | Temperature[°C(°F)] | Resistance [kΩ] |
|---|---|---|---|
| -40 (-40) | 41.74 to 54.54 | 80 (176) | 0.31 to 0.33 |
| -20 (-4) | 14.13 to 16.83 | 140 (284) | 0.07 to 0.08 |
| 0 (32) | 5.28 to 6.3 | ||
| 25 (68) | 1.88 to 2.14 |
Good
- Go to "VERIFICATION OF REPAIR " procedure.
No Good
- Carefully re-do this troubleshooting guide steps.
- If no problems were found with the circuits or connectors, replace the FRPS and go to "VERIFICATION OF REPAIR " procedure.