■ Actuation Test 

  1. Connect GDS to Data Link Connector (DLC).
  2. IG "ON".
  3. Perform "Motor" in the "Actuation Test  " with GDS.
  4. Listen carefully for motor operating sound.

    Specification:  Motor operating sound is heard

    Fig 1: Motor Actuation Test - Screen Display
    G11796001Courtesy of KIA MOTORS AMERICA, INC.
  5. Do the valve operates as intended?

    YES 

    • Fault might be intermittent caused by poor connection and/or HECU's connector or was repaired and HECU memory was not cleared. Thoroughly check connectors for looseness, poor connection, bending, corrosion, contamination, deterioration, or damage. Repair or replace as necessary and then go to "Verification Of Vehicle Repair " procedure.

    NO 

    • Substitute with a known-good HECU and check for proper operation.

      If the problem is corrected, replace HECU and then go to "Verification Of Vehicle Repair " procedure.

    NOTE: * In case of replacing HECU, perform following procedures.
    1. "ASP Calibration" for steering angle sensor offset correction.
    2. "Longitudinal G-Sensor Calibration" for Longitudinal sensor offset correction. (refer to C1285 )
    3. "Perform Variant Coding". (refer to C1702 )
    Item Detecting Condition Possible cause
    DTC Strategy
    • Signal Monitoring
    1. Faulty Yaw Sensor
    2. Open or short of Yaw Sensor
    Case 1 Monitoring Period
    • Continuous (during stable driving)
    Threshold Value
    • In case of stable driving condition, difference between measured yaw sensor value and calculated yaw sensor value is over 3.5 deg, system enters suspicious mode. And suspicious mode is continued for maximum of 120 sec, fault is set
    Case 2 Monitoring Period
    • Continuous (during standstill)
    Threshold Value
    • In case of standstill, monitoring a fault if it is more than 7.0 m/s2 to the difference between previous lateral G offset and the mean of lateral G offset estimated from other sensors
    Case3 Monitoring Period
    • Continuous (during driving)
    Threshold Value
    • In case of straight and stable driving over 30kph, monitoring a fault if it is more than 2.5m/s2 to the difference between previous lateral G offset and mean of lateral G offset estimated from other sensors.
    Case4 Monitoring Period
    • Continuous (during driving)
    Threshold Value
    • In case of stable driving, monitoring a suspicious mode if it is more than 3.5 deg to the difference between measured Yaw sensor values and Yaw values estimated from other sensors. If suspicious mode is held on, a fault is set. (max. 120sec)
    Case5 Monitoring Period
    • Continuous (during standstill)
    Threshold Value
    • In case of standstill, monitoring a fault if it is more than 3deg/sec to the difference between previous Yaw offset and the mean of Yaw offset estimated from other sensors.
    Case6 Monitoring Period
    • Continuous (during driving)
    Enable Conditions
    • In case of straight and stable driving over 30kph, monitoring a fault if it is more than 3deg/sec to the difference between previous Yaw offset and mean of Yaw offset estimated from other sensors.
    Case7 Monitoring Period
    • Continuous (no under voltage fault after IGN On)
    Threshold Value
    • llateral G sensor valuel > 15 m/s2,
      • fault detection time: keep the value for 1s
    • Δlateral G sensor value > 11 m/s2
      • fault detection time: keep the difference value for 120 ms
    • lYaw sensor Valuel > 30 deg/sec, for 5s on first standstill

      lYaw sensor Valuel > 95 deg/sec, for 1s on driving

    • ΔYaw sensor value > (10~25 deg/sec)
      • fault detection time: keep the difference value (ΔYaw sensor value) for 120 ms
    Case8 Monitoring Period
    • Continuous
    Threshold Value
    • Monitoring a fault if it is more than 4.5m/s2 to the difference between longitudinal G sensor value and the mean of Yaw offset estimated from other sensors for more than 2s.
    Case9 Monitoring Period
    • Continuous (during standstill)
    Threshold Value
    • llongitudinal G sensorl > 15 m/s2, For moer than 800ms
    Fail Safe
    • Inhibit the ESP (ESC) control and allow the ABS/EBD control
    • The ESP (ESC) warning lamps are activated