LEMON Manuals: Even more car manuals for everyone
Home >> Kia >> 2016 >> Forte EX >> Repair and Diagnosis >> Brakes >> Traction Control >> Electric Stability Program Diagnosis >> DTC C2308: Front-LH Valve Error (Inlet Valve) >> Component Inspection >> Verification Of Vehicle Repair

Verification Of Vehicle Repair

■ Actuation Test 

  1. Connect GDS to Data Link Connector (DLC).
  2. IG "ON".
  3. Perform "Inlet Valve-Left Front" in the "Actuation Test  " with GDS.
  4. Listen carefully for valve operating sound.

    Specification:  "Tik" sound is heard

    Fig 1: Inlet Valve-Left Front Actuation Test - Screen Display
    G11795977Courtesy of KIA MOTORS AMERICA, INC.
  5. Do the valve operates as intended?

    YES 

    • Fault might be intermittent caused by poor connection and/or HECU's connector or was repaired and HECU memory was not cleared. Thoroughly check connectors for looseness, poor connection, bending, corrosion, contamination, deterioration, or damage. Repair or replace as necessary and then go to "Verification Of Vehicle Repair " procedure.

    NO 

    • Substitute with a known-good HECU and check for proper operation.

      If the problem is corrected, replace HECU and then go to "Verification Of Vehicle Repair " procedure.

    NOTE: * In case of replacing HECU, perform following procedures.
    1. "ASP Calibration" for steering angle sensor offset correction.
    2. "Longitudinal G-Sensor Calibration" for Longitudinal sensor offset correction. (refer to C1285 )
    3. "Perform Variant Coding". (refer to C1702 )